{"created":"2023-05-15T08:36:27.472379+00:00","id":1388,"links":{},"metadata":{"_buckets":{"deposit":"9655fadd-984b-4539-a8a9-04091d0d3565"},"_deposit":{"created_by":1,"id":"1388","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"1388"},"status":"published"},"_oai":{"id":"oai:tsukuba-tech.repo.nii.ac.jp:00001388","sets":["63:64"]},"author_link":["15782"],"control_number":"1388","item_1693536256228":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-03-06"}],"displaytype":"detail","filename":"gakuju010_zhang_001.pdf","filesize":[{"value":"277 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"gakuju010_zhang_001.pdf","url":"https://tsukuba-tech.repo.nii.ac.jp/record/1388/files/gakuju010_zhang_001.pdf"},"version_id":"91b7e8f5-10e5-431b-89d5-c510b151a454"}]},"item_3_alternative_title_21":{"attribute_name":"タイトルヨミ","attribute_value_mlt":[{"subitem_alternative_title":"チュウゴク ニ オケル セツビ セッケイ ト シュミレーション ヨウ キショウ データベース ニ カンスル ケンキュウ ダイ 2 ホウ ニッシャ リョウ ノ スイテイ ト 360 チテン ニ オケル レイボウ セッケイ ニッシャ リョウ","subitem_alternative_title_language":"ja"}]},"item_3_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-08-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"161","bibliographicPageEnd":"17","bibliographicPageStart":"11","bibliographic_titles":[{"bibliographic_title":"空気調和・衛生工学会論文集"}]}]},"item_3_date_64":{"attribute_name":"最初の登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2011-01-11"}]},"item_3_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究は中国における設備設計とシミュレーション用気象データベースを開発することを目的とする.本報では, 1995年~2005年間の毎時日射量を推定し,その推定精度を検証した.次に,得られた毎時日射量に対して統計処理を行い,危険率が2.5%となる毎時日射量を算出し,冷房設計日射量とした.また,水平面全天日射量の時刻別変動率をsin(hi)比で近似し,360地点の夏季設計日射量をピーク時日射量とsin(hi)比によってパターン化した.さらに,夏季設計日射量の直達成分と天空成分を明らかにし,sin(hi)比によるパターン化を試み,それによる10時~16時間の推定誤差が6.0%以内であることがわかった.","subitem_description_type":"Abstract"}]},"item_3_description_7":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"空気調和・衛生工学会論文集 161","subitem_description_type":"Other"}]},"item_3_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"空気調和・衛生工学会"}]},"item_3_rights_14":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"当論文は発行元の許諾を得て、掲載しております"}]},"item_3_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00065706","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-275X","subitem_source_identifier_type":"PISSN"}]},"item_3_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"産業技術学部産業情報学科"}]},"item_3_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"張, 晴原","creatorNameLang":"ja"},{"creatorName":"チョウ, セイゲン","creatorNameLang":"ja-Kana"},{"creatorName":"Zhang, Qingyuan","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"統計処理","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"中国における設備設計とシミュレーション用気象データベースに関する研究:第2報日射量の推定と360地点における冷房設計日射量","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"中国における設備設計とシミュレーション用気象データベースに関する研究:第2報日射量の推定と360地点における冷房設計日射量","subitem_title_language":"ja"}]},"item_type_id":"3","owner":"1","path":["64"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-01-11"},"publish_date":"2011-01-11","publish_status":"0","recid":"1388","relation_version_is_last":true,"title":["中国における設備設計とシミュレーション用気象データベースに関する研究:第2報日射量の推定と360地点における冷房設計日射量"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2024-03-25T00:36:17.797569+00:00"}