{"created":"2023-05-15T08:36:23.306254+00:00","id":1309,"links":{},"metadata":{"_buckets":{"deposit":"26fea6fd-f720-4677-9e35-cc61538e361d"},"_deposit":{"created_by":1,"id":"1309","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"1309"},"status":"published"},"_oai":{"id":"oai:tsukuba-tech.repo.nii.ac.jp:00001309","sets":["63:64"]},"author_link":["15782","19450"],"control_number":"1309","item_1693536256228":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2023-09-05"}],"displaytype":"detail","filename":"gakuju95_zhang_004.pdf","filesize":[{"value":"629 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"gakuju95_zhang_004.pdf","url":"https://tsukuba-tech.repo.nii.ac.jp/record/1309/files/gakuju95_zhang_004.pdf"},"version_id":"f6e456de-7682-4f40-ba83-ce3736728f1e"}]},"item_3_alternative_title_21":{"attribute_name":"タイトルヨミ","attribute_value_mlt":[{"subitem_alternative_title":"クールチューブ ノ セッケイ デグチ オンド ト レイキャク エネルギー リョウ ノ ケントウ クールチューブ ニ ヨル シツナイ ネツ カンキョウ ノ カイゼン ニ カンスル ケンキュウ ダイ 2 ホウ","subitem_alternative_title_language":"ja"}]},"item_3_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1995-11-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"18","bibliographicPageStart":"11","bibliographicVolumeNumber":"477","bibliographic_titles":[{"bibliographic_title":"日本建築学会計画系論文集"}]}]},"item_3_date_64":{"attribute_name":"最初の登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2011-09-07"}]},"item_3_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"One of the main reasons for the fact that cooling tubes are not being widely used is lack of data for designing the tubes. The purpose of this paper is to supply such basic data to designers. Firstly, 10 main cities in Japan are selected for the discussion of exit temperature and cooling energy of cooling tubes. Then, the thermal behavior of cooling tubes located in these cities is simulated. Regression analyses are carried out to predict the exit temperature of cooling tubes. Lastly the values of cooling energy for open and closed loops are presented.","subitem_description_type":"Abstract"}]},"item_3_description_7":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"日本建築学会計画系論文集","subitem_description_type":"Other"}]},"item_3_publisher_36":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人日本建築学会"}]},"item_3_relation_16":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://ci.nii.ac.jp/naid/110004654155"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110004654155","subitem_relation_type_select":"URI"}}]},"item_3_rights_14":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_3_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10438548","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1340-4210","subitem_source_identifier_type":"PISSN"}]},"item_3_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"筑波技術短期大学建築工学科"},{"subitem_text_value":"熊本大学建築学科"}]},"item_3_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"張, 晴原","creatorNameLang":"ja"},{"creatorName":"チョウ, セイゲン","creatorNameLang":"ja-Kana"},{"creatorName":"Zhang, Qingyuan","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"石原, 修","creatorNameLang":"ja"},{"creatorName":"イシハラ, オサム","creatorNameLang":"ja-Kana"},{"creatorName":"Ishihara, Osamu","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"クールチューブ","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"クールチューブの設計出口温度と冷却エネルギー量の検討 : クールチューブによる室内熱環境の改善に関する研究 第2報","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"クールチューブの設計出口温度と冷却エネルギー量の検討 : クールチューブによる室内熱環境の改善に関する研究 第2報","subitem_title_language":"ja"}]},"item_type_id":"3","owner":"1","path":["64"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-09-07"},"publish_date":"2011-09-07","publish_status":"0","recid":"1309","relation_version_is_last":true,"title":["クールチューブの設計出口温度と冷却エネルギー量の検討 : クールチューブによる室内熱環境の改善に関する研究 第2報"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2024-03-25T02:56:29.368750+00:00"}